Motor Types

IM

Tick
Tick

PM

Tick
Tick

BLDC

Tick
Tick

SynRM

Tick
Tick

LSPM

Tick
Tick

PMAREL

Tick

Voltage & Power Ratings

110V 1ph input / 110V 1ph output

0.37-0.55kW
0.37-0.55kW

110V 1ph input / 230V 3ph output

0.37-1.1kW
0.37-1.1kW

230V 1ph input / 230V 1ph output

0.37-1.1kW
0.37-1.1kW

230V 1ph input / 230V 3ph output

0.37-4kW
0.37-2.2kW

230V 3ph input / 230V 3ph output

0.37-18.5kW
0.37-2.2kW

110–115V 1ph input / 200–240V 1ph input

0.37-1.1kW

200–240V 1 or 3ph input

0.37-2.2kW

400V 3ph input / 400V 3ph output

0.75-22kW
4kW

Overload

Overload capacity

150% 60 sec’s
150% 60 sec’s

Ambient Conditions

Temperature

-20 to +50oC
-20 to +50oC

Humidity

95% Max non-condensing
95% Max non-condensing

Enclosure

IP20

Tick
Tick

IP66

Tick

Nema 1 Kit

Tick

Programming

Keypad

Built-in/Optional remote keypad
Built-in/Optional remote keypad

Display

LED
LED

Comissioning Connectivity

RJ45

Tick
Tick

USB-C support

Tick

Remote keypad

Tick
Tick

Control Specification

PWM frequency

2-16 kHz
2-16 kHz (0.1 kHz adjustable)

Torque control

Tick

Built-in Fieldbus Connectivity

CANopen

Tick
Tick

Modbus RTU

Tick
Fixed parity
Tick
Odd/Even parity selection

BACnet MS/TP

Tick

Plug-in Module Fieldbus Connectivity

Ethernet-IP

Tick

Modbus-TCP

Tick

PROFINET

Tick

Ethercat

Tick

On-Board Flight recorder

On-Board flight recorder

Tick

I/O Specification

NPN/PNP logic selection

Tick

Freely programmable inputs

Tick

Dedicated digital inputs

2
2

Digital/Analog inputs

2
2

Digital/Analog outputs

1
1

Relay outputs

1
1 Changeover

24V keep alive

Tick

24V user output capacity

100mA
150mA

STO

Tick

Braking

AC flux braking

Tick
Tick

DC injection braking

Tick
Tick

Independent start/stop for dc injection

Tick

Dynamic braking

Size 2 and larger
Size 2 and larger

Software based braking resistor protection

Tick

Mechanical brake control

Basic
Advanced (Torque prove)

Motor Connected check Capacity

Motor connected check

Tick

Input Phase loss detection Prior to running

Input phase loss detection prior to running

Tick

Application Features

PI (D) Control

Tick
Tick

Fire mode

Tick
Tick

Master/Slave

Tick
Tick

Sequencer

Tick

s-curve adjustment

Tick

Power limit

Tick

Belt brake protection

Tick

Low load/Flow detection

Tick

Pump stir

Tick

DC bus sharing

Sz2+only
Tick

Real units (e,g Bar) for PI setup vs %

Tick

Standby/Sleep mode

Tick
Adjustable standby frequency

Spin start

Tick
All motor types

Auto-back EMF measurement

Tick

Skip frequency

Tick
Tick

Side by side mounting

Tick

Microprocessor

Basic
Advanced (Faster processing power for higher efficiency Motors)