MVX Specification
Supply
Mains Voltage
MVXxxxx-V12
Rated Frequency
Rated Power Frequency Withstand Voltage (Ud)
MVXxxxx-V12
Rated Lightning Impulse Withstand Voltage (Up)
MVXxxxx-V12
Rated short-time withstand current (asymmetrical RMS peak) (Ik)
MVXxxxx-V12
Form Designation
Control Inputs
Start (Terminals C23, C24)
Stop (Terminals C31, C32)
Reset (Terminals C41, C42)
Input A (Terminals C53, C54)
Input B (Terminals C63, C64)
Motor Thermistor (Terminals B4, B5)
Control Outputs
Relay Outputs
6 A @ 250 VAC AC15 p.f. 0.3
10 A @ 30 VDC resistive
Main Contactor (Terminals 13, 14)
Bypass Contactor (Terminals 23, 24)
Run Output/ PFC (Terminals 33, 34)
Output Relay A (Terminals 43, 44)
Output Relay B (Terminals 51, 52, 54)
Output Relay C (Terminals 61, 62, 64)
Analog Output (Terminals B10, B11)
Environmental
Equipment Class (EMC)
Internal Arc Classification (IAC)
Degree of Protection
Phase Cassette
Controller
Operating Environment
IEC60721-3-3: IE34: Climatic 3K4
Relative Humidity
Storage Environment
IEC60721-3-1: IE12
Relative Humidity
Pollution Degree
Vibration
Standards Approvals
C√
CE
MVX Protection Codes
Code | Protection description | MVX Protection (built-in) |
---|---|---|
48 | Maximum start time | Excess start time |
66 | Too many starts | Restart delay and dynamic thermal model |
37 | Undercurrent | |
51L | Load Increase (alarm) | High current frequency output |
51R | Overcurrent - jam | Excess start time, electronic shearpin |
50 | Overcurrent - short | Shorted SCR, electronic shearpin |
49/51 | Thermal overload | Thermal overload - dynamic model |
46 | Current imbalance | Current imbalance |
Positive/negative phase sequence | Phase sequence | |
27 | Undervoltage | Undervoltage |
59 | Overvoltage | Overvoltage |
47 | Phase loss | Phase loss |
47 | Phase sequence | Phase sequence |
50G | Ground fault | Ground fault |
3 | Communications failure | Communications failure |
3 | Internal failure | Internal failure |
86/97 | Ext. fault 1/code - 1 | Auxiliary trip A |
Ext. fault 1/code - 2 | Auxiliary trip B | |
38 | Motor overtemperature | Thermistor protection* |
49 | Stator winding overtemperature | Thermistor protection* |
32 | Under power | Power Loss |
* RTD Relay is an optional extra.